Preparation:
|
2060 Cartridge: |
Step 1 Position the pliers or a wrench on the flat sides of the cartridge nut and rotate counter-clockwise to remove the cartridge nut. |
Step 2 Slide the cartridge out of the brass valve body. |
Step 3 Position the new cartridge so the two feet on the bottom of the cartridge line up with the two matching indents inside the valve body. Slide the cartridge into the valve body. |
Step 4 Slide the cartridge nut into the valve body and position the pliers or wrench on the flat sides of the cartridge nut. Rotate the cartridge nut clockwise until it is tight, then rotate it an additional 1/8 turn. |
Step 5 Use the pliers or wrench to rotate the brass cartridge stem so that the flat side with the round indent is facing upward. |
For additional information on Moen products visit solutions.moen.com and select the type of product you are repairing. The guide will contain repair details, troubleshooting and specific information on assembling handles associated with that style of product.