To protect a home from water damage when access to Wi-Fi® is not available, Local Mode can be utilized.

Users can manually program leak detection sensitivity and perform health tests with the installed unit. (Note: unit must be connected to AC power and installed on a pressurized pipe.)

Snag_1574c66.png

 

1. RESET BUTTON

Snag_15917ee.png

2. VALVE LED

Snag_1597030.png

3. STATUS LED

Snag_159cbed.png

Below are the detailed instructions on how you can set the local mode:

To Open Valve
Snag_1df59af.png   Reset Button: Snag_1dfef57.png   Status LED: Snag_1e0516d.png   Valve LED: Result: Note:
Press 1X   Snag_1dd21c0.png Valve opens To close the valve, push and turn knob with your hand or hex key.
To Select Leak Detection Sensitivity (Valve must be open. If indicated thresholds have been met, the device will automatically shut off the water.)
For devices manufactured before 01/31/2023
Snag_1e0e976.png   Reset Button: Snag_1e16a10.png   Status LED: Snag_1e1c967.png   Valve LED: Result: Note:

Press 1X

Snag_1cf6593.png  

HIGH Leak Detection (default)

Auto Shut-Off at:

  • 10 gal consumed*
  • 5gpm for 10+ sec
  • 5 min of water use*

Select HIGH if little to no water use is expected in the home.

Press 2X

Snag_1cf860c.png  

MEDIUM Leak Detection

Auto Shut-Off at:

  • 20 gal consumed*
  • 5gpm for 10+ sec
  • 10 min of water use*

Select MEDIUM if some water use is expected in the home.

Press 3X

Snag_1cf9dca.png  

LOW Leak Detection

Auto Shut-Off at:

  • 50 gal consumed*
  • 8gpm for 10+ sec
  • 15 min of water use*

Select LOW if significant water usage is expected in the home.

*in a single event

To Select Leak Detection Sensitivity (Valve must be open. If indicated thresholds have been met, the device will automatically shut off the water.)
For devices manufactured after 01/31/2023
Snag_1e0e976.png   Reset Button: Snag_1e16a10.png   Status LED: Snag_1e1c967.png   Valve LED: Result: Note:

Press 1X

Snag_1cf9dca.png  

LOW Leak Detection (default)

Auto Shut-Off at:

  • 50 gal consumed*
  • 8gpm for 10+ sec
  • 15 min of water use*

Select LOW if significant water usage is expected in the home.

Press 2X

Snag_1cf860c.png  

MEDIUM Leak Detection

Auto Shut-Off at:

  • 20 gal consumed*
  • 5gpm for 10+ sec
  • 10 min of water use*

Select MEDIUM if some water use is expected in the home.

Press 3X

Snag_1cf6593.png

 

HIGH Leak Detection

Auto Shut-Off at:

  • 10 gal consumed*
  • 5gpm for 10+ sec
  • 5 min of water use*

Select HIGH if little to no water use is expected in the home.

*in a single event

To Run Health Test (Valve must be open. The valve will turn off and the health test will run for 5 minutes or less)
Snag_1e4d09c.png   Reset Button: Snag_1e52246.png   Status LED: Snag_1e54501.png   Valve LED: Result: Note:
Press 5X Snag_1e66ae3.png   Pass No leaks found.
Press 5X Snag_1e6a174.png   Interrupted** Test was disrupted due to water being used. Re-test when water is not being used in the house.
Press 5X Snag_1e6b569.png   Fail** Drip or leak detected.

 Once health test is complete, press reset button once to reset Status LED light.

  LED Lights During Standard Operation
 

 

Snag_154ebb2.png

Status LED

 

Snag_14a5a5f.png Blinking light = water is flowing normally.

 

 Snag_14d6c72.png Steady light = water flow is obstructed. Check waterway and flow turbine.

 