How to use the Local Mode
To protect a home from water damage when access to Wi-Fi® is not available, Local Mode can be utilized. Users can manually program leak detection sensitivity and perform health tests with the installed unit. (Note: unit must be connected to AC power and installed on a pressurized pipe.) |
1. RESET BUTTON
2. VALVE LED 3. STATUS LED |
Below are the detailed instructions on how you can set the local mode:
To Open Valve |
Reset Button: | Status LED: | Valve LED: | Result: | Note: |
---|---|---|---|---|
Press 1X | Valve opens | To close the valve, push and turn knob with your hand or hex key. |
To Select Leak Detection Sensitivity (Valve must be open. If indicated thresholds have been met, the device will automatically shut off the water.) For devices manufactured before 01/31/2023 |
Reset Button: | Status LED: | Valve LED: | Result: | Note: |
---|---|---|---|---|
Press 1X |
HIGH Leak Detection (default) Auto Shut-Off at:
|
Select HIGH if little to no water use is expected in the home. |
||
Press 2X |
MEDIUM Leak Detection Auto Shut-Off at:
|
Select MEDIUM if some water use is expected in the home. |
||
Press 3X |
LOW Leak Detection Auto Shut-Off at:
|
Select LOW if significant water usage is expected in the home. |
*in a single event
To Select Leak Detection Sensitivity (Valve must be open. If indicated thresholds have been met, the device will automatically shut off the water.) For devices manufactured after 01/31/2023 |
Reset Button: | Status LED: | Valve LED: | Result: | Note: |
---|---|---|---|---|
Press 1X |
LOW Leak Detection (default) Auto Shut-Off at:
|
Select LOW if significant water usage is expected in the home. |
||
Press 2X |
MEDIUM Leak Detection Auto Shut-Off at:
|
Select MEDIUM if some water use is expected in the home. |
||
Press 3X |
|
HIGH Leak Detection Auto Shut-Off at:
|
Select HIGH if little to no water use is expected in the home. |
*in a single event
To Run Health Test (Valve must be open. The valve will turn off and the health test will run for 5 minutes or less) |
Reset Button: | Status LED: | Valve LED: | Result: | Note: |
---|---|---|---|---|
Press 5X | Pass | No leaks found. | ||
Press 5X | Interrupted** | Test was disrupted due to water being used. Re-test when water is not being used in the house. | ||
Press 5X | Fail** | Drip or leak detected. |
Once health test is complete, press reset button once to reset Status LED light.
LED Lights During Standard Operation |
Status LED |
Blinking light = water is flowing normally.
Steady light = water flow is obstructed. Check waterway and flow turbine.
**For additional assistance with Local Mode, or for help understanding your health test, reach out to your local Moen sales rep, call 1-844-MEETFLO or email support@meetflo.com. |
1. RESET BUTTON
2. VALVE LED 3. STATUS LED |