Moen Sump Pump Monitor Status LED, Beeper and Siren
Status LED | Description | Meaning |
---|---|---|
Status LED is solid Yellow. |
Device is not able to connect with your network. |
|
Status LED is solid Green. |
Device connected to your network. |
|
Status LED is blinking Yellow: half a second on, then 9 and a half seconds off. Beeper: Beeps in a low pitch tone for 2 seconds once. |
Device is running on battery power. Check main power source. |
|
Status LED is blinking Yellow: 1 second on, then 4 seconds off. Beeper: Beeps in a low pitch tone for 0.5 second, then off for 600 seconds |
Battery power low. Replace battery when convenient |
|
Status LED is blinking Yellow: 1 second on, then 1 second off. Beeper: Beeps in a low pitch tone for 0.5 second, then off for 600 seconds |
Battery dead. Replace battery to ensure proper operation. |
|
Status LED is blinking Amber and Blue. |
The device is broadcasting a network in an attempt to configure with your mobile device. |
|
Status LED is blinking White. |
The device is in the process of upgrading to the latest software. |
|
Status LED is blinking Red, half second on, then half second off. Siren stays on. |
Water in the sump crock is above overflow water level or water detected by leak sensor. Take immediate action. |
|
Status LED is blinking Red, half second on, then half second off. Beeper: Beeps in a high pitch tone for 0.5 second, then off for 3 seconds |
Water in the sump crock is above high water level. Backup should be running. |
|
Status LED is blinking Red, 1 second on, then 1 second off. |
Failed to read water level from sensor. Check connection. |