Skip to main content
Moen Solutions

Shower Handle: 3/4" Exact Temp-Thermostatic Lever

​ 

clipboard_e0c194cc03015a29ba96f8606263b9a3f.png
This article will give step-by-step instructions on how to install a 3/4" Exact Temp-Thermostatic Lever

Preparation:


 

clipboard_eb0dc3825e9af1f2b5f79baece1e4a5f9.png

 

Disassembly:

  1. Gently remove the override cap (#1).
  2. Unthread the red temperature override screw with the included o-ring (#2).
  3. While holding the lever stationary, unthread unthread the middle section of the handle body (#3) counterclockwise from the valve.

2020-09-25_12-37-35.gif

Assembly:

  1. While holding the lever stationary, thread unthread the middle section of the handle body (#3) clockwise onto the valve.
  2. Thread the red temperature override screw (#2) until it sits flush with outer edge of the handle assembly (#3) 
  3. Reinstall the override cap(#1).

For additional information on Moen products visit solutions.moen.com and select the type of faucet you are repairing. The faucet guide will contain repair details, troubleshooting and specific information on assembling handles associated with that style of product.


Still Not Finding What You're Looking For?

Contact Us or Call 1-800-BUY-MOEN           