Skip to main content
Moen Solutions

Cartridge Replacement: 252005 Free Standing


Preparation:


Snag_1ed35b8.png

Parts Legend:

A-Cartridge Nut

B-Cartridge

C-Valve Body

 

Disassembly:

  1. Using pliers, unthread and remove the brass cartridge nut (A).
  2. To remove, pull on the cartridge stem (B), 

It is recommended to clean and flush the valve body (C) prior to installing the new cartridge (B). See article Valve Body Cleaning and Flushing for additional details

Assembly:

  1. Align the two posts on the cartridge (B) to the mating feature on the valve body (C) and push the cartridge (B) into the valve body (C) until it stops. 

  1. Using pliers, thread the brass cartridge nut (A) back in.

For additional information on Free Standing Tub Fillers, visit Roman Tub Filler: Free Standing Floor Mount at solutions.moen.com.


Still Not Finding What You're Looking For?

Contact Us or Call 1-800-BUY-MOEN           